Energy Monitoring Hardware

Precision Energy Intelligence

Three-phase metering for power quality, supply reliability, and energy management, installed in distribution boxes, on transformers, or non-invasively on industrial machines.

Electra EMS300

A purpose-built, three-phase smart energy meter with integrated split-core CT clamps. Installs directly in distribution boxes, on transformers, or non-invasively on industrial machines, streaming high-resolution power data to the Electra cloud.

Voltage

3×230/400V AC

Connectivity

4G-LTE / Wi-Fi / LoRa

Accuracy

Class 0.5S

Standard

IEC 62053-22

THE PROBLEM

Bad power doesn't announce itself. A transformer ages a year in a month. Tenants dispute bills no one can verify. An outage clears and no one can prove how long it lasted. From utility feeders to estates and factory floors, most operators don't measure their power, they pay for it, in shortened asset life, disputed revenue, and incidents that get blamed on everything but the wire.

01 — Visibility

See what conventional meters miss

Voltage sags, brownouts, and harmonic distortion leave no trace on standard billing meters. The EMS300 logs every event from the 2nd to the 31st order; so the first time you hear about a transient isn't from a damaged motor.

02 — Evidence

Outage timing you can prove

Every outage and restoration is timestamped on-device, even when the network is down. Compute SAIFI/SAIDI from real data — not estimates — and settle disputes with regulators, operators, or tenants on evidence.

Cost of Disruption / hours
24h
Operation Status
Passenger KiosksUnstable
Bagage HallsUnstable
Boarding SystemsUnstable
03 — Decision

Decisions on data, not assumptions

Visibility into events. Evidence on timing. Together, they become the layer your operations run on. Every EMS300 computes power quality and reliability metrics on-device and feeds a single Electra dashboard, so the same data you used to detect a sag is the data you use to schedule the maintenance, settle the dispute, or rebalance the feeder.

What it measures.

EMS300 Standalone

No additional hardware required. Class 0.5S accuracy.

  • Phase Voltage (V)
  • Line Voltage (V)
  • Frequency (Hz)
  • Voltage Harmonic Distortion (THDv) — 2nd to 31st order
  • Voltage Unbalance
  • Undervoltage / Overvoltage
  • Outage & Restoration Events
  • Supply Reliability Index

EMS300 + CT Clamp

Split-core / Rogowski Coils, 100A–6000A. Class 0.5S or Class 1.

  • Phase Current (A)
  • Active Energy (kWh)
  • Real Power (kW)
  • Reactive Power (kVAR)
  • Apparent Power (kVA)
  • Power Factor
  • Current Harmonic Distortion (THDi) (%)
  • Current Unbalance
  • Leakage & Neutral Current (A)
  • Underload / Overload / Peak Load (kW)

Connected out of the box.

Communication

Wireless
4G-LTE / Wi-Fi / LoRa
Wired
RS485 (A, B) · MODBUS-RTU
Digital Inputs
4× (DI1–DI4) · built-in +12V supply
Relay Outputs
2× (DO1, DO2) · remote control & alarms
Temperature
Phase A · B · C · Neutral
Local Storage
On-device logging during network outages

Wiring Configurations

  • 3P 4-wire via CT
  • 3P 3-wire via CT
  • 3P 4-wire via PT + CT
  • 3P 3-wire via PT + CT

Where it's deployed.

From utility distribution networks to industrial floors, EMS300 adapts to the environments that need it most.

01

Supply Reliability

Continuous logging of outage events, restoration times, and SAIFI/SAIDI indices on transformers, feeders, and distribution points.

02

Energy Management

Per-circuit active energy metering for sub-billing, consumption benchmarking, and load profiling across facilities.

03

Power Quality

Measurement of voltage/current harmonics up to the 31st order, phase imbalance, power factor, and transient fault events for manufacturing plants, IPPs, and distribution companies.

04

Operational Efficiency

Performance analysis, cost-per-kWh analysis, and OEE tracking for mini-grids, embedded IPPs, and C&I solar operators.

Trusted By Many

Join leading organizations across the globe who rely on Electra for real-time energy intelligence and grid optimization.

87MW

Capacity Monitored

Active capacity under continuous monitoring across estates, industrial facilities, and distribution networks, with every kWh and supply event timestamped at the meter.

99.9%

System Uptime

Redundant edge-computing architecture providing 99.9% availability for mission-critical energy infrastructure, ensuring zero-latency telemetry even in remote environments.

31ORDER

Harmonic Resolution

Voltage and current harmonic analysis from the 2nd to the 31st order detects transients, phase imbalance, and early-stage insulation failures invisible to standard SCADA systems.

150+

Global Assets

A growing network of industrial complexes, green hydrogen facilities, and sovereign utility grids leveraging Electra's autonomous optimization engines for net-zero transition.

Stop paying for power you can't see.

Talk to our team about deploying the EMS300 across your feeders, estates, or facility — and start measuring what matters.

Request a Demo